UV-CURE
Standard axis oriented in-chamber UV Sensor
The ”UV-Cure” is an axial looking sensor with a male threaded body (M22x1.5) for measurement of high UV radiation to control i.e. curing or drying processes where strong UV light is present. It has an integrated temperature sensor and a diffuser made of radiation hard and temperature resistant microporous quartz glass. The sensor contains
integrated electronics and is shielded against electromagnetic interference. Sensor confi guration options are spectral response, signal output type and measuring range.
The signal output is either a voltage of 0 to 5 V, a current of 4 to 20 mA, CAN bus interface or USB. The UV sensor is available with a NIST or PTB traceable calibration.
Technical specifications
Spectral Sensitivity: Broadband UV, UVA, UVB, UVC, UV-Index, Bluelight and UV+VIS
Signal Output: 0 to 5 V or 4 to 20 mA or CAN bus signal (125kbit/s) or USB
Current Consumption: for 0 to 5 V = < 30 mA / for 4 to 20 mA = signal out / digital = < 17 mA
Connections: cable = 2 m cable with tinned leads on free end
plug = 5 pin male connector with 2 m cable with tinned leads on free end
CAN = 2 m cable with 8 pin male connector (to converter or else)
USB = with 1.5 m cable with USB-A plug
Measuring Range: between 1 nW/cm2
to 1 µW/cm2 and 20 mW/cm2 to 20 W/cm2
for analog or 100 µW/cm2 to 20 W/cm2 for digital sensors (see questionaire sheet)